Auth-1034; Auth-1035; Auth-1036 - Brocade Communications Systems A7533A - Brocade 4Gb SAN Switch Base Reference Manual

Brocade error message reference guide v6.1.0 (53-1000600-02, june 2008)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

3

AUTH-1034

Probable Cause
Indicates that an entity was not configured in the switch connection control (SCC) policy and tried
to connect to the port.
Recommended
Add the entity's world-wide name (WWN) to the SCC policy and reinitialize authentication by using
Action
the portDisable and portEnable commands or the switchDisable and switchEnable commands.
Severity
ERROR
AUTH-1034
Message
<timestamp>, [AUTH-1034], <sequence-number>,, ERROR, <system-name>, Failed to
validate name <entity name> in <authentication message>: port <port number>.
Probable Cause
Indicates that the specified entity name in the payload is not in the correct format.
Recommended
Reinitialize authentication using the portDisable and portEnable commands or the switchDisable
Action
and switchEnable commands.
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity
ERROR

AUTH-1035

Message
<timestamp>, [AUTH-1035], <sequence-number>,, ERROR, <system-name>, Invalid <data
type> length in <message phase> message: length <data length>, port <port number>.
Probable Cause
Indicates that a particular data field in the authentication message has an invalid length field. This
error usually relates to internal failure.
Recommended
Usually this problem is transient. The authentication might fail.
Action
Reinitialize authentication using the portDisable and portEnable commands or the switchDisable
and switchEnable commands.
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity
ERROR

AUTH-1036

Message
<timestamp>, [AUTH-1036], <sequence-number>,, ERROR, <system-name>, Invalid state
<state value> for <authentication phase>: port <port number>.
Probable Cause
Indicates that the switch received an unexpected authentication message.
Recommended
Usually this problem is transient. The authentication might fail.
Action
Reinitialize authentication using the portDisable and portEnable commands or the switchDisable
and switchEnable commands.