Ag-1001; Ag-1002; Ag-1003; Ag System Messages - Brocade Communications Systems A7533A - Brocade 4Gb SAN Switch Base Reference Manual

Brocade error message reference guide v6.1.0 (53-1000600-02, june 2008)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

AG System Messages

AG-1001

Message
<timestamp>, [AG-1001], <sequence-number>,, ERROR, <system-name>, N_Port ID
virtualization (NPIV) is not supported by fabric port connected to port <port>.
Probable Cause
N_Port ID virtualization (NPIV) capability is not supported by the fabric port to which the Access
Gateway is connected.
Recommended
Action
Severity
ERROR

AG-1002

Message
<timestamp>, [AG-1002], <sequence-number>,, WARNING, <system-name>, Unable to
find alternate N_Port during failover for N_Port <port>.
Probable Cause
No other N_Port is configured or the fabric was unstable during failover.
Recommended
Please check whether or not an alternate N_Port is configured.
Action
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity
WARNING

AG-1003

Message
<timestamp>, [AG-1003], <sequence-number>,, WARNING, <system-name>, Unable to
failover N_Port <port>. Failover across different fabrics is not supported.
Probable Cause
Failover across N_Ports connected to different fabrics is not supported.
Recommended
Please configure two or more N_Ports to connect to the same fabric; then execute
Action
ag --failoverenable to enable failover on these N_Ports.
Fabric OS Message Reference
53-1000600-02
On switches running Fabric OS 6.0 or earlier versions, run the portCfgNpivPort command to
enable NPIV capability on the port connected to the Access Gateway. Refer to the Fabric OS
Command Reference manual for more information on this command.
Some blades and ports in a switch may not support NPIV. NPIV functionality cannot be enabled
on such ports and they will not respond to NPIV requests. Refer to the Access Gateway
Administrator Guide, Appendix B for specific AG compatibility requirements.
On non-Brocade switches, refer to the manufacture's documentation to determine whether the
switch supports NPIV and how to enable NPIV on these types of switches.
Chapter
2
23

Advertisement

Table of Contents
loading

Table of Contents