5
BL-1027
Recommended
Collect supportSave information, then reboot switch and run the diagPost command to ensure
Action
Power-On Self-Test (POST) is enabled. If problem persists, replace switch.
Severity
CRITICAL
BL-1027
Message
<timestamp>, [BL-1027], <sequence-number>,, CRITICAL, <system-name>, Blade in
slot <slot number> faulted, boot failed; status 0x<boot status> 0x<1250 0 boot
status> 0x<1250 1 boot status>.
Probable Cause
Indicates that the blade failed to boot properly.
Recommended
Reboot or power cycle the blade.
Action
If the message persists, replace the blade.
Severity
CRITICAL
BL-1028
Message
<timestamp>, [BL-1028], <sequence-number>,, CRITICAL, <system-name>, Switch
faulted; internal processor was reset before switch init completed.
Probable Cause
Indicates that the switch's internal processor was reset before the initialization completed.
Recommended
Reboot or power cycle the switch.
Action
If the message persists, replace the switch.
Severity
CRITICAL
BL-1029
Message
<timestamp>, [BL-1029], <sequence-number>,, INFO, <system-name>, All ports on the
switch will be reset as part of the firmware upgrade.
Probable Cause
Indicates that a recent firmware upgrade caused the switch's internal processor firmware to be
upgraded and resulted in the cold upgrade. As part of the upgrade, all the datapath elements were
reset.
Recommended
No action is required.
Action
Severity
INFO
56