Bl-1030; Bl-1031; Bl-1032; Bl-1033 - Brocade Communications Systems A7533A - Brocade 4Gb SAN Switch Base Reference Manual

Brocade error message reference guide v6.1.0 (53-1000600-02, june 2008)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

BL-1030

Message
<timestamp>, [BL-1030], <sequence-number>,, INFO, <system-name>, All GigE/FCIP
Virtualization/FC Fastwrite ports on the switch will be reset as part of the
firmware upgrade.
Probable Cause
Indicates that a recent firmware upgrade caused the switch's internal processor firmware to be
upgraded and resulted in the cold upgrade. As part of the upgrade, all the GigE/Fibre Channel over
IP (FCIP)/Virtualization data elements / FC Fastwrite ports were reset.
Recommended
No action is required.
Action
Severity
INFO

BL-1031

Message
<timestamp>, [BL-1031], <sequence-number>,, CRITICAL, <system-name>, Link timeout
in internal port (slot <Slot number>, port <Port number>) resulted in blade fault.
Use slotpoweroff/slotpoweron to recover the blade.
Probable Cause
Indicates that link timeout occurred in one of the backend internal ports.
Recommended
Power cycle the blade or run the slotPowerOff and slotPowerOn commands.
Action
Severity
CRITICAL

BL-1032

Message
<timestamp>, [BL-1032], <sequence-number>,, CRITICAL, <system-name>, (slot <slot
number>,bitmap 0x<object control flags(bitmap)>) ports never came up ONLINE
(reason <reason for port disable>, state <status of the blade>). Disabling slot.
Probable Cause
Indicates that back-end (non-user) ports have not come ONLINE within time limit.
Recommended
Reboot or power cycle the blade. Run the systemVerification command to verify that the blade does
Action
not have hardware problems. Run the diagPost command to ensure that Power-On Self-Test (POST)
is enabled. If the message persists, replace the blade.
Refer to the Fabric OS Command Reference for more information on the systemVerification
command.
Severity
CRITICAL

BL-1033

Message
<timestamp>, [BL-1033], <sequence-number>,, CRITICAL, <system-name>, (slot <slot
number>,bitmap 0x<object control flags(bitmap)>) No disable acknowledgment from
ports (state <status of the blade>). Disabling slot.
Fabric OS Message Reference
53-1000600-02
5
BL-1030
57

Advertisement

Table of Contents
loading

Table of Contents