Make sure that the blade is seated correctly.
Action
If the blade is seated correctly, reboot or power cycle the blade.
Run the systemVerification command to verify that the blade does not have hardware problems.
Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. Refer to the Fabric
OS Command Reference for more information on these commands.
If the message persists, replace the blade.
Severity
CRITICAL

BL-1017

Message
<timestamp>, [BL-1017], <sequence-number>,, INFO, <system-name>, Slot
number>
Probable Cause
Indicates that the slot has started initializing the ports.
Recommended
No action is required.
Action
Severity
INFO

BL-1018

Message
<timestamp>, [BL-1018], <sequence-number>,, INFO, <system-name>, Slot
number>
Probable Cause
Indicates that the slot has completed initializing the ports.
Recommended
No action is required.
Action
Severity
INFO

BL-1019

Message
<timestamp>, [BL-1019], <sequence-number>,, INFO, <system-name>, Slot <Slot
number>, retry <Retry Number>, internal port retry initialization, <List of
internal ports retrying initialization>.
Probable Cause
Indicates that the slot had internal ports not online and that the system is retrying to bring the
ports that failed back online.
Recommended
No action is required.
Action
Severity
INFO