ZONE-1007

Message
<timestamp>, [ZONE-1007], <sequence-number>,, INFO, <system-name>,
Ioctl(<function>) in (<error message>) at port (<port number>) returns code
(<error string>) and reason string (<reason string>).
Probable Cause
Indicates that frame filter logic reported a failure during one of the IOCTL calls. The IOCTL call from
which the failure is reported is listed as part of the error message. This is usually a programming
error when adding content-addressable memory (CAM) entries before the filter setup.
Recommended
There are two ways to avoid this problem.
Action
Severity
INFO

ZONE-1008

Message
<timestamp>, [ZONE-1008], <sequence-number>,, WARNING, <system-name>, WARNING -
port
Probable Cause
Indicates that the total number of entries of S_ID CAM is above the limit while creating or adding a
zone group. The maximum number of content-addressable memory (CAM) entries allowed depends
on the application-specific integrated circuit (ASIC).
Recommended
If hardware zoning enforcement is preferred, edit the zoning database to have zoned PIDs for that
Action
port.
Severity
WARNING

ZONE-1010

Message
<timestamp>, [ZONE-1010], <sequence-number>,, WARNING, <system-name>, WARNING -
Duplicate entries in zone(
Probable Cause
Indicates that there are duplicate entries in a zone object. A zone object member is specified twice
in a given zone object. This message occurs only when enabling a zone configuration.
Recommended
Check the members of the zone and delete the duplicate member.
Action
Severity
WARNING

ZONE-1012

Message
<timestamp>, [ZONE-1012], <sequence-number>,, WARNING, <system-name>, WARNING -
All ports are offline.
Probable Cause
Indicates that all the ports in a zone are offline.
Fabric OS Message Reference
53-1000600-02
Avoid having too many hosts zoned with a set of target devices at a single port.
Avoid having too many zones directed at a single port group on the switch.
<port number>
Out of CAM entries.
<zone name>
) specification.