AG-1004

Severity
WARNING
AG-1004
Message
<timestamp>, [AG-1004], <sequence-number>,, ERROR, <system-name>, Invalid
response to fabric login (FLOGI) request from the fabric for N_Port <port>.
Probable Cause
Indicates that the fabric sent an invalid response to the FLOGI Extended Link Service (ELS) for the
specified N_Port.
Recommended
Please check the configuration of the fabric switch.
Action
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity
ERROR

AG-1005

Message
<timestamp>, [AG-1005], <sequence-number>,, WARNING, <system-name>, FDISC
response was dropped because F_Port <port> is offline.
Probable Cause
Indicates that the F_Port connected to the host is offline, which caused the FDISC response to
drop.
Recommended
Please check the configuration of the host connected to the specified F_Port.
Action
Severity
WARNING

AG-1006

Message
<timestamp>, [AG-1006], <sequence-number>,, INFO, <system-name>, Access Gateway
mode has been <msg>.
Probable Cause
Access Gateway mode has been enabled or disabled.
Recommended
Please run ag --modeshow to verify the current status of the Access Gateway mode.
Action
Severity
INFO

AG-1007

Message
<timestamp>, [AG-1007], <sequence-number>,, WARNING, <system-name>, FLOGI
response not received for the N_Port
Probable Cause
Indicates that the N_Port connected to the fabric switch is not online. The specified N_Port has
been disabled.
24
<port>
connected to the fabric.
Fabric OS Message Reference
53-1000600-02