Download  Print this page

HP 438031-B21 - 1:10Gb Ethernet BL-c Switch Application Manual Page 159

Hp 1:10gb ethernet bl-c switch for c-class bladesystem application guide.
Hide thumbs

Advertisement

Configure RMON Alarms (BBI example 1)
1.
Configure an RMON Alarm group.
Click the Configure context button.
a.
Open the Switch folder, and select RMON > Alarm > Add Alarm Group.
b.
Configure RMON Alarm Group parameters to check ifInOctets on port 20 once every hour.
c.
Enter a rising limit of two billion, and a rising event index of 6. This configuration creates an
RMON alarm that checks ifInOctets on port 20 once every hour. If the statistic exceeds two
billion, an alarm is generated that triggers event index 6.
2.
Click Submit.
Remote monitoring
159

Advertisement