Intel® Compute Module MFS5520VI TPS
Fault LED
This column indicates whether an assertion of an event lights the front panel fault LED. The
Integrated BMC aggregates all fault sources (including outside sources such as the BIOS) such
that the LED will be lit as long as any source indicates that a fault state exists. The Integrated
BMC extinguishes the fault LED when all sources indicate no faults are present.
Sensor Rearm
The rearm is a request for the event status for a sensor to be rechecked and updated upon a
transition between good and bad states. Rearming the sensors can be done manually or
automatically. The following abbreviations are used in the column:
'A': Auto rearm
'M': Manual rearm
Readable
Some sensors are used simply to generate events into the System Event Log. The Watchdog
timer sensor is one example. These sensors operate by asserting and then immediately de-
asserting an event. Typically the SDRs for such sensors are defined such that only the assertion
causes an event message to be deposited in the SEL. Reading such a sensor produces no
useful information and is marked as 'No' in this column. Note that some sensors may actually be
unreadable in that they return an error code in response to the IPMI Get Sensor Reading
command. These sensors are represented by type 3 SDR records.
Standby
Some sensors operate on standby power. These sensors may be accessed and/or generate
events when the compute module payload power is off, but standby power is present.
Sensor Name
Sensor #
Power Unit Status
Watchdog
Revision 1.5

Table 17. MFS5520VI Sensors

Sensor Type
Event/Reading
Power Unit
01h
09h
Watchdog 2
03h
23h
Intel order number: E64311-007
Appendix B: Integrated BMC Sensor Tables
Event Offset
Type
Triggers
00 - Power down
04 - A/C lost
Sensor
05 - Soft power
Specific
control failure
6Fh
06 - Power unit
failure
Sensor
00 - Timer
Specific
expired, status
only
6Fh
01 - Hard reset
02 - Power down
03 - Power cycle
Contrib. To
Rearm
Stand-by
System Status
OK
A
OK
A
X
X
37