7 To ignore the display setting, select Ignore from the Action drop-down list.
In this case, the not standardized display setting will not be listed again in future updates, except if you
select Show objects set to ignore during project standards synchronization or remove the Ignore flag from
the display setting in Display Manager, as described in
on page 480.
8 Click OK.
9 In Display Manager, click OK or Apply.
10 Click Yes to save the updated project standards drawing.
Editing the Version History of a Standard Display Setting
Each display setting in a project standards drawing has a version history. The version history displays the unique version
identifier, date and time of the modification, user name and any additional comments entered by the user.
You can edit the history by selectively removing individual versions, or removing all versions. You cannot remove the
current version.
1 Open a project standards drawing.
2 On the Format menu, click Display Manager.
3 Select a standard display setting from the project node.
4 Click the Version History tab.
5 To add a new version, click Version, and enter the versioning information.
6 To remove an existing version, select the version from the Version History list, and click Remove.
To remove all versions in one step, click Remove All.
7 If you want the display setting to be ignored during synchronization of standards, select Ignore during
project standards synchronization.
8 Click OK.
Purging the Version History from a Project Standards Drawing
You can remove the version history from all standard styles and display settings in a project standards drawing with
one command. Purging the version history will remove all versions except the current one from the standard styles
and display settings. You can do that to avoid cluttering your styles and display settings.
When you purge the version history, no version GUID except for the current one remains. That means that the
synchronization can no longer separate between an older version of a standard display setting and a non standard
version of a standard display setting. Each display setting in a project drawing that does not have the current GUID of
the corresponding standard display setting, will be labeled a non-standard", or newer version.
1 Open the project standards drawing.
2 On the command line, enter AecClearVersionHistory.
484 | Chapter 10 Display System
Excluding Display Settings from
Synchronization"
Need help?
Do you have a question about the 24108-051400-9000 - AutoCAD Revit Architecture Suite 2008 and is the answer not in the manual?