Message
Error 235: Unrecognized Command
The CLI does not recognize the command and cannot perform the
Description
help '?' command as requested.
The entered command is misspelled or the prompt is not positioned
Action
at the right place in the CLI command tree for this command. For the
appropriate syntax, see the section of the manual that corresponds to
the attempted command.
Message
Error 236: Ambiguous Command
The CLI does not recognize the command issued.
Description
The CLI cannot interpret the command because a unique match
Action
cannot be identified. For the appropriate syntax, see the section of the
manual that corresponds to the attempted command. Enter the
complete command and re-submit.
Message
Error 237: Invalid Zoning Database
There was an unidentifiable problem in the local zone set work area.
Description
Verify all parameters are entered correctly and re-submit. Otherwise,
Action
the pending zone set should be cleared and reconstructed.
Message
Error 238: Invalid Feature Key
The feature key entered is invalid.
Description
Verify that the feature key was entered correctly and re-submit.
Action
Contact your service representative with further difficulties.
Message
Error 239: Fabric binding entry not found
The user requested to remove a fabric binding entry that is not in the
Description
pending fabric membership list.
Verify that the correct entry (both WWN and Domain ID) is being
Action
requested for removal from the list and re-submit the request.