Issues in JUNOS Release 10.1 for M Series, MX Series, and T Series Routers
The following messages are displayed on both the primary and secondary RLSQ
MS 500 PICs: "SCHED: %PFE-0: Thread 7 ran for x ms without yielding,"
"Scheduler Oinker." [PR/286357: This issue has been resolved.]
CFMD might crash when the following are configured and commited at once on
a VPLS setup:
Encapsulation VLAN-VPLS on a physical and logical interface
Family VPLS on a logical unit
Interface is added in the VPLS routing instance
As a workaround, add the above configurations one at a time and commit.
[PR/440108: This issue has been resolved.]
If virtual tunnel PICs and ingress traffic manager is enabled on the same Packet
Forwarding Engine/PIC on an EQ DPC, then the SNMP walk of the interface may
time out. [PR/458565: This issue has been resolved.]
In some cases during the periodic error status monitoring, error messages such
as "Wi seg ucode discards in fabric stream" may be displayed on adjacent
streams. These messages are cosmetic and can be ignored. [PR/481344: This
issue has been resolved.]
When loopback is configured on t3 under ct3, t1 under ct1, or e1 under ce1, no
error syslog message is logged. Additionally, the
command on the t3/t1/e1 displays "loopback" even though it is not actually
applied. [PR/486424: This issue has been resolved.]
The DPC remains in the ready state and the demux0 interface remains in a down
state after a chassisd restart without graceful Routing Engine switchover (GRES)
enabled. [PR/492961: This issue has been resolved.]
The AE logical interface flaps when the PIC that has the active link-protection
member link is taken offline. [PR/493492: This issue has been resolved.]
The No Redundant Config alarm that occurs in JUNOS Release 10.0 and above
after a PEM is shut down is invalid and is a non-impacting alarm message.
[PR/498089: This issue has been resolved.]
The one port OC12-3 PIC cannot support eight queues when the
option is configured. [PR/499452: This issue has been resolved.]
On a 4–port ChOC3/STM1 and 12–port T1/E1 circuit emulation PICs, the ATM
logical interface packets counter does not increment if the PIC is configured in
the ATM IMA mode. [PR/500153: This issue has been resolved.]
When t1-options are configured at the
some ct1 interfaces of a 10xCHT1 IQ PIC might flap when the configuration
changes are committed. As a workaround, remove the t1-options. [PR/500820:
This issue has been resolved.]
Polling
ifInOctets
on Gigabit Ethernet IQ PIC VLANs might momentarily return a
higher value. [PR/500852: This issue has been resolved.]
show interface extensive
hierarchy level,
[edit interfaces ct1-x/y/z]
no-concatenate

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the JUNOS 10.1 - RELEASE NOTES REV 4 and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Networks junos 10.1

Table of Contents