JUNOS 10.1 Software Release Notes
Infrastructure
Integrated Convergence Services
The following issues currently exist in SRX210 and SRX240 devices with Integrated
Convergence Services:
150
Issues in JUNOS Release 10.1 for SRX Series Services Gateways and J Series Services Routers
On SRX240 devices, the Mini-PIM LEDs glow red for a short duration (1 second)
when the device is powered on. [PR/429942]
On SRX240 devices, the file installation fails on the right USB slot when both of
the USB slots have USB storage devices attached. [PR/437563]
On SRX240 devices, the combinations of Mini-PIMs cause SFP-Copper links to
go down in some instances during bootup, restarting fwdd, and restarting
chassisd. As a workaround, reboot the device and the link will be up. [PR/437788]
On SRX5600 devices, during a Routing Engine reboot when processes are being
shut down, a rare race condition occurs that can lead to a Routing Engine kernel
crash. [PR/488484]
On J Series devices, you cannot use a USB device that provides U3 features (such
as the U3 Titanium device from SanDisk Corporation) as the media device during
system boot. You must remove the U3 support before using the device as a boot
medium. For the U3 Titanium device, you can use the U3 Launchpad Removal
Tool on a Windows-based system to remove the U3 features. The tool is available
for download at
http://www.sandisk.com/Retail/Default.aspx?CatID=1415
the U3 features, use the U3 Launchpad Installer Tool accessible at
http://www.sandisk.com/Retail/Default.aspx?CatID=1411
On J Series devices, if the device does not have an ARP entry for an IP address,
it drops the first packet from itself to that IP address. [PR/233867]
On J Series devices, when you press the F10 key to save and exit from BIOS
configuration mode, the operation might not work as expected. As a workaround,
use the Save and Exit option from the Exit menu. This issue can be seen on the
J4350 and J6350 routers with BIOS Version 080011 and on the J2320 and J2350
routers with BIOS Version 080012. [PR/237721]
On J Series devices, the
Clear NVRAM
does not work as expected. This issue can be seen on the J4350 and J6350 routers
with BIOS Version 080011 and on the J2320 and J2350 routers with BIOS Version
080012. To help mitigate this issue, note any changes you make to the BIOS
configuration so that you can revert to the default BIOS configuration as needed.
[PR/237722]
On J Series devices, If you enable security trace options, the log file might not
be created in the default location at
manually set the log file to the directory
On SRX3400, SRX3600, SRX5600, and SRX5800 devices, the SNMP set for the
MIB object
usmUserPrivKeyChange
). [PR/102645]
option in the BIOS configuration mode
. As a workaround,
/var/log/security-trace
/var/log/security-trace
does not work. [PR/482475]
. (To restore
. [PR/254563]