JUNOS 10.1 Software Release Notes
14
New Features in JUNOS Release 10.1 for M Series, MX Series, and T Series Routers
(and so on) is not supported. Use the offline procedures to upgrade and integrate
the remaining T1600 routers into the routing matrix.
[TX Matrix Plus Hardware, System Basics and Services Command Reference]
Per-unit scheduling for GRE tunnels using IQ2 PICs (M7i, M10i, M120, and
M320 routers with E3 FPC) Supports enhanced IQ2 PIC and IQ2E PIC
performance, adding all functionality of tunnel PICs. The QoS for the GRE tunnel
traffic will be applied as the traffic is looped through the IQ2/IQ2E PIC.
Shaping is performed on full packets that pass through the GRE tunnel.
IQ2 and IQ2E PICs support all interfaces that are supported on tunnel PICs, as
follows:
gr-fpc/pic/port
vt-fpc/pic/port
lt-fpc/pic/port
ip-fpc/pic/port
pe-fpc/pic/port
pd-fpc/pic/port
mt-fpc/pic/port
The port variable is always zero.
The provided tunnel functionality is the same as that of regular tunnel PICs.
When tunnel services are enabled on IQ2 and IQ2E PICs, they work exclusively
as tunnel PICs. The physical ports on the PICs cannot be used in tunnel mode.
To configure exclusive tunnel mode, use the
hierarchy level.
fpc number pic number]
You can use the
show interfaces queue gr-fpc/pic/port
statistics for the specified tunnel.
[Network Interfaces, Class of Service, PIC Guide]
Root System Domain (RSD) configuration of logical interface filters on shared
interfaces (JCS1200 platform) Enables Root System Domain (RSD) configuration
support for logical interface filters on shared interfaces. In previous releases,
logical interface filters were configured on each Protected System Domain (PSD).
This release supports configuration on the RSD.
To configure a logical interface filter on the RSD, apply the firewall filter to the
logical interface on the shared interface by including the
statement at the
[edit interfaces interface-name unit logical-unit-number]
level on the RSD.
Filtering is performed on the PSD, but logical interface filters configured on the
RSD are applied automatically by the PSD. Filters configured on the RSD can
co-exist with filters configured on the PSD. Counter statistics related to PSD
filtering are available on the RSD.
[Protected System Domain]
tunnel-only
statement at the
command to display
filter output filter-name
[chassis
hierarchy
Need help?
Do you have a question about the JUNOS 10.1 - RELEASE NOTES REV 4 and is the answer not in the manual?