Errata and Changes in Documentation for JUNOS Release 10.1 for SRX Series Services Gateways and J Series Services Routers

Hardware Documentation

Errata and Changes in Documentation for JUNOS Release 10.1 for SRX Series Services Gateways and J Series Services
For a J Series Services Router, if the buffer size percentage is set to zero for T1
interfaces, traffic does not pass.
On SRX100 devices, the Alarm LED is off, indicating that the device is starting
up.
Note that when the device is on, if the Alarm LED is off, it indicates that no
alarms are present on the device.
The "Configuring Basic Settings for the SRX100 Services Gateway with a
Configuration Editor" section in the SRX100 Services Gateway Hardware Guide
contains the following inaccuracies:
The documentation incorrectly implies that the management port and
loopback address must be defined for the device.
The documentation should indicate that the SSH remote access can be
enabled.
The documentation indicates the CLI command
incorrect. The correct command is
The J-Web Initial Set Up screenshot shown in the SRX210 Services Gateway Getting
Started Guide and the SRX240 Services Gateway Getting Started Guide contains
the following inaccuracies: The J-Web screenshot incorrectly shows the "Enable
DHCP on ge-0/0/0.0" check box as disabled in factory default settings. The J-Web
screenshot should indicate the "Enable DHCP on ge-0/0/0.0" check box as enabled
in factory default settings.
The
show chassis environment cb 0
Gateway Hardware Guide is modified to
The Power over Ethernet section in the SRX210 Services Gateway Hardware Guide
incorrectly states that PoE+ support (IEEE 802.3at standard) is available on all
models of SRX210 devices.
The guide should state that
PoE (IEEE 802.3 af) support is enabled only on the SRX210 Services Gateway
PoE model.
PoE+ (IEEE802.3 at) support is enabled only on the SRX210 Services
Gateway with Integrated Convergence Services model.
The DOCSIS Mini-Physical Interface Module chapter in the SRX Series Services
Gateways for the Branch Physical Interface Modules Hardware Guide erroneously
states that EuroDOCSIS 3.0 and DOCSIS J (Japan) models of the DOCSIS Mini-PIM
are supported. The guide should state that only DOCSIS 3.0 US model of DOCSIS
Mini-PIM is supported.
set services ssh
set system services ssh
command mentioned in the SRX5600 Services
show chassis environment cb node 0