Outstanding Issues in JUNOS Release 10.1 for EX Series Switches

The following are outstanding issues in JUNOS Release 10.1R3 for EX Series switches.
The identifier following the description is the tracking number in our bug database.
NOTE: PRs 300576, 403842, 409934, 415569, 415748, 429589, 440611, 455670,
and 488318, which were included in the earlier release notes as outstanding issues,
have been removed, because these issues are not applicable to JUNOS Release 10.1R3
for EX Series switches.

Access Control and Port Security

Bridging, VLANs, and Spanning Trees

Class of Service

Outstanding Issues in JUNOS Release 10.1 for EX Series Switches
The
show interface detail | extensive
packets or bytes for the transit statistics and traffic statistics counters. You can
use the counter information displayed under the
output.
When a virtual management Ethernet (VME) interface is used as a default gateway
and the VME interface is the indirect next hop for any route, the route might not
change dynamically and could always point to the VME interface.
New Features in JUNOS Release 10.1 for EX Series Switches on page 186
Changes in Default Behavior and Syntax in JUNOS Release 10.1 for EX Series
Switches on page 189
Outstanding Issues in JUNOS Release 10.1 for EX Series Switches on page 193
Resolved Issues in JUNOS Release 10.1 for EX Series Switches on page 196
Errata in Documentation for JUNOS Release 10.1 for EX Series Switches on
page 199
Upgrade and Downgrade Issues for JUNOS Release 10.1 for EX Series Switches
on page 200
If you configure the RADIUS server
not attempt to reconnect to the unreachable server after the revert interval has
elapsed. [PR/304637]
There might be traffic loss on VLANs learned through MVRP during GRES. After
the GRES, there will not be any traffic loss. [PR/458303]
On EX2200 switches, CoS port-shaping can yield different shaping results on
uplink ports than on normal network ports when the same shaping rate is used.
[PR/453660]
Outstanding Issues in JUNOS Release 10.1 for EX Series Switches
command might display double counting of
Physical interface
revert-interval interval
option, the switch does
section of the