Displaying The Module Status - Dell PowerConnect B-RX16 Installation Manual

Bigiron rx series
Table of Contents

Advertisement

TABLE 13
LED
Fan control module (two LEDs on rear panel of chassis)
Unlabeled
If a problem persists after taking action described in this table, contact Brocade for technical
support.

Displaying the module status

After you have attached a PC or terminal to the management module's Console port or Ethernet
port and the BigIron RX Series switch has initialized successfully, press Enter to display the
following CLI prompt in the terminal emulation window:
BigIron RX>
BigIron RX Installation Guide
53-1001811-01
Desired and abnormal LED states after system power on (Continued)
Desired state
Meaning
Green (steady)
The fans are working
and responding to
controls from the fan
control module.
Verifying proper operation
Abnormal
Meaning or action
state
Off or amber
The fans are not receiving power
(off), or the fans are not working
and not responding to controls
from the fan control module
(amber). You can do the following:
If the LED is off, check the
power LED on the other
modules to make sure they
are receiving power.
If using a DC power source,
check your power source for
problems.
If using AC power supplies,
take the actions described in
the Meaning or Action
column for the AC power
supply LED. If these actions
do not resolve the problem,
check the LED on each power
supply or enter the show
chassis command at any CLI
prompt to determine if a
power supply has failed. If a
power supply has failed, you
need to replace it. For more
information, refer to
"Replacing a power supply"
on page 147.
If the LED is amber, you need
to replace the fan module.
For information about
performing these tasks, see.