Monitoring The Cooling System - Dell PowerConnect B-RX16 Installation Manual

Bigiron rx series
Table of Contents

Advertisement

5
Managing the cooling system
low – The system sets the fan speed to low.
med – The system sets the fan speed to medium.
med-high – The system sets the fan speed to medium-high.

Monitoring the cooling system

You can monitor the following aspects of the BigIron RX Series cooling system:
Displaying fan tray status and speed
The CLI provides two commands that allow you to display the status and speed of the four-speed
fans in the BigIron RX Series chassis. To display this information, you can enter the following
command at any level of the CLI:
BigIron RX# show chassis
...
--- FANS ---
Right Fan Tray: Fan 5: Status = OK, Speed = LOW (50%) (RPM 3333)
Right Fan Tray: Fan 6: Status = OK, Speed = LOW (50%) (RPM 3488)...
Syntax: show chassis
For information about all output generated by the show chassis command,refer to
chassis status and temperature readings"
TABLE 22
This field...
Status
Speed
Displaying temperature warnings
If the temperature of a module exceeds the high temperature threshold for any of the fan speeds,
the system sends a warning message to the system log and an SNMP trap. (For more information
about the low and high temperature thresholds, refer to
modules and fan speeds"
have configured the BigIron RX Series system to use a Syslog server or SNMP trap receiver, refer to
the documentation for the server or receiver.
122
The temperature of the fan control modules
The status and speed of the fans
The temperature warnings sent to the system log and that generate an SNMP trap
Fan status and speed fields
Displays...
The status can be one of the following:
OK – The fan is functioning properly and is keeping the temperature of each module within
an acceptable temperature range.
Failed – The fan is not functioning properly or the fan control module cannot control the
fan.
The speed can be one of the following:
LOW – The fan is functioning at 50 percent of capacity
MEDIUM – The fan is functioning at 75 percent of capacity
MEDIUM-HIGH – The fan is functioning at 90 percent of capacity
HIGH – The fan is functioning at 100 percent of capacity
on page 117.) This section describes how to view the system log. If you
on page 113.
"Changing temperature thresholds for
"Displaying
BigIron RX Installation Guide
53-1001811-01