To display the system log, enter the following command at any CLI level:
BigIron RX# show log
Syntax: show log

Managing the interface modules

This section contains the following information:

Configuring interface module boot parameters

The Ethernet interface module has its own system software and boots after the management
module boots. By default, the following boot-related events occur:
If desired, you can change the following:
Synchronizing the interface module's IronWare images between
management and interface modules
An interface module can have two IronWare images: primary and secondary. These images contain
the layer 1 – 3 software that the interface modules run. These images reside in the interface
module's flash memory. Either the primary or secondary image is run by the interface module from
this location.
If you copy the primary or secondary IronWare image to all interface modules using the copy
command with the all keyword, the management module makes a copy of the file and stores it in
its code flash under the names lp-primary-0 or lp-secondary-0. The images are stored in this
location only and are not run by the management module or the interface modules. If you copy the
primary or secondary IronWare image to a specified chassis slot using the copy command with the
<chassis-slot-number> parameter, the management module does not make a copy of the file.
If the management module has a copy of the primary or secondary IronWare image in its code
flash, by default, the BigIron RX Series system synchronizes or prompts you to synchronize the
interface modules' IronWare images between the management module and the interface modules
during bootup. When the BigIron RX Series system synchronizes the IronWare images, the
management module copies the IronWare images from its code flash to the interface modules'
code flash (the interface modules' default boot source).
BigIron RX Installation Guide
53-1001811-01
Configuring interface module boot parameters
Changing the priority of chassis slots for interface modules
Disabling and reenabling power to the interface modules
The BigIron RX Series system synchronizes or prompts you to synchronize the interface
modules' IronWare images between the management module and the interface modules.
The interface modules boot from a source specified by the management module (the default
source is a primary IronWare image in the interface modules' flash memory).
Disable the synchronization of IronWare images between the management and all interface
modules. You can also initiate an immediate synchronization.
Change the boot source of one or all interface modules.