Dell PowerConnect B-RX16 Installation Manual page 44

Bigiron rx series
Table of Contents

Advertisement

2
Installing a BigIron RX-4 switch
3. Starting with the chassis that you want to mount in the lowest position in the rack, mount the
FIGURE 19
1
4. Slide the chassis down so that the screw heads are in the narrow portion of the keyhole slots.
5. Tighten the screws to secure the chassis in place.
NOTE
To provide better grounding of the chassis to the rack, attach the chassis to the rack using star
washers. Additionally, if any single hole grounding lugs are used star washers shall be used as a
means to prevent rotation of the lug.
6. Add additional screws as required.
7.
Removing the slot blanks
The BigIron RX-4 chassis ships with slot blanks installed in all module slots. The slot blank covers a
slot that does not currently have a module installed in it, ensuring proper airflow within the chassis.
If you plan to install a module in a particular slot, you must remove the slot blank.
CAUTION
If you do not install a module in a slot, you must keep the slot blank in place. If you run the
chassis with an uncovered slot, the system may overheat. Tighten the screws that secure the slot
blanks so that they remain in place when removing adjacent panels or modules.
32
chassis in the rack as shown in
wide portion of each keyhole slot over the corresponding screw in the rack.
Mounting the BigIron RX-4 or BigIron RX-8 chassis in a rack
Standard 19 inch rack
Repeat
step 2
through
step 6
Figure
19. With two or more people lifting the chassis, slip the
to mount each subsequent chassis in the same rack.
1
BigIron RX Installation Guide
53-1001811-01