TABLE 18
This field...
Status
Speed
Temperature Readings
Active and Standby Mgmt Module
Fan <number>
SNM<number>
Temperature Monitoring Poll Period
Misc Info
Backplane EEPROM MAC Address
Displaying the Syslog configuration and static and
dynamic buffers
For information about configuring Syslog, refer to the BigIron RX Series Configuration Guide
To display the Syslog parameters currently in effect on a BigIron RX Series switch, enter the
following command from any level of the CLI:
BigIron RX> show logging
Syslog logging: enabled (0 messages dropped, 0 flushes, 0 overruns)
...
Syntax: show logging
The Syslog display shows the following configuration information, in the rows above the log entries
themselves.
TABLE 19
This field...
Syslog logging
messages dropped
BigIron RX Installation Guide
53-1001811-01
Chassis status and temperature information (Continued)
Buffer logging: level ACDMEINW, 7 messages logged
level code: A=alert C=critical D=debugging M=emergency E=error
I=informational N=notification W=warning
Syslog buffer configuration
Managing the BigIron RX Series chassis
Displays...
The status of a fan can be one of the following:
OK – The fan is functioning properly and is keeping the temperature of
each module within an acceptable temperature range.
Failed – The fan is not functioning properly or the fan control module
cannot control the fan.
The speed of a fan can be one of the following:
Low – The fan is functioning at 50 percent of capacity.
Medium – The fan is functioning at 75 percent of capacity.
Medium-high – The fan is functioning at 90 percent of capacity.
High – The fan is functioning at 100 percent of capacity.
The temperature of the active and standby management modules.
The temperature of fan0 and fan1.
The temperature of the switch fabric module.
The interval at which the system reads the temperature sensor on the
management, switch fabric, interface, and fan control modules.
The MAC address of the BigIron RX Series chassis.
Displays...
The state (enabled or disabled) of the Syslog buffer.
The number of Syslog messages dropped due to user-configured filters.
By default, the software logs messages for all Syslog levels. You can
disable individual Syslog levels, in which case the software filters out
messages at those levels. Each time the software filters out a Syslog
message, this counter is incremented.