Upgrading The Interface Module's Monitor And Boot Images - Dell PowerConnect B-RX16 Installation Manual

Bigiron rx series
Table of Contents

Advertisement

2. Copy the new IronWare image from the TFTP server or a flash card in slot 1 or 2 to the
3. Verify that the new IronWare image has been successfully copied to the specified destination
4. If you want to upgrade other software images, go to the appropriate upgrade section for

Upgrading the interface module's monitor and boot images

NOTE
We recommend that you perform this upgrade procedure from a PC or terminal that is directly
connected to the management module's Console port. You can also perform this procedure through
a Telnet or SSHv2 session.
Follow the steps given below to upgrade an interface's monitor and boot images simultaneously.
1. Place the new monitor and boot images on a TFTP server to which the BigIron RX Series system
2. Copy the new monitor and boot images to the BigIron RX Series. Enter one of the following
TABLE 29
Command syntax
copy tftp lp <ip-addr> <image-name>monitor all |
<slot-number>
copy tftp lp <ip-addr> <image-name>monitor
copy-boot all | <slot-number>
3. Verify that the new images were successfully copied to code flash by entering the following
BigIron RX Installation Guide
53-1001811-01
management module's code flash or a flash card in slot 1 or 2. To perform this step, enter one
of the following commands at the Privileged EXEC level of the CLI:
copy tftp flash <ip-addr> <image-name> primary | secondary
copy tftp slot1 | slot2 <ip-addr> <image-name> primary | secondary
copy slot1 | slot2 flash <image-name> primary | secondary
copy slot1 | slot2 slot1 | slot2 <image-name> <dest-name>
For information about the image name to specify, refer to
by entering one of the following commands at the Privileged EXEC level of the CLI:
show flash (if the destination was code flash)
dir /<path-name>/ (if the destination was slot 1 or 2)
Check for the primary or secondary image and the date and time that it was placed in the
directory.
information. If you have completed upgrading the software images, you must reboot the
management module to complete the upgrade process. For more information, refer to
"Rebooting the management module"
has access or on a PCMCIA flash card inserted in slot 1 or 2.
commands at the Privileged EXEC level of the CLI (example: BigIron RX
Command syntax for upgrading the monitor and boot images on the interface module
For information about the image name to specify, refer to
command at the Privileged EXEC level of the CLI:
show flash
Upgrading the BigIron RX Series software
Table
24.
on page 183.
Description
Copies the latest monitor image from the TFTP server to all
interface modules or to the specified interface module
(slot-number).
Copies the latest monitor and boot images from the TFTP
server to all interface modules or to the specified interface
module (slot-number).
Table
24.
7
):
#
181

Advertisement

Table of Contents
loading

Table of Contents