<dd:hh:mm> is the number of days, hours, and minutes.
primary | secondary specifies whether the reload is to occur from the primary code flash module or
the secondary code flash module.
Displaying the amount of time remaining before a scheduled
reload
To display how much time is remaining before a scheduled system reload takes place, use one of
the following methods.
To display how much time is remaining before a scheduled system reload, enter the following
command from any level of the CLI:
BigIron RX# show reload
Canceling a scheduled reload
To cancel a scheduled system reload, enter the following command at the Privileged EXEC level of
the CLI:
BigIron RX# reload cancel
Diagnostic error codes and remedies for TFTP transfers
If an error occurs with a TFTP transfer to or from a BigIron RX Series switch, one of the following
error codes are displayed.
TABLE 30
Error
code
1
2
3
4
5
6
BigIron RX Installation Guide
53-1001811-01
Diagnostic error codes and remedies for TFTP transfers
Diagnostic error codes
Message
Flash read preparation failed.
Flash read failed.
Flash write preparation failed.
Flash write failed.
TFTP session timeout.
TFTP out of buffer space.
Explanation and action
A flash error occurred during the download.
Retry the download. If it fails again, contact
customer support
TFTP failed because of a time out.
Check IP connectivity and make sure the TFTP
server is running.
The file is larger than the amount of space on the
device or TFTP server.
If you are copying an image file to flash, first copy
the other image to your TFTP server, then delete it
from flash. (Use the erase flash... CLI command at
the Privileged EXEC level to erase the image in the
flash.)
If you are copying a configuration file to flash, edit
the file to remove unneeded information, then try
again.
7