XG700 User's Guide
Fan (fan status)
Rear Fan-1
Rear Fan-2
PWR-1 (fan installed in power supply unit 1)
PWR-2 (fan installed in power supply unit 2)

6.1.2 Verifying System Status

Verify the status of system by entering the
administrator EXEC mode.
The following example shows the information that is displayed when the
xg# show system information
System Information 2005/08/22-21:06:11
=======================================
System Name (hostname) : xg
System Location
System Contact
Default Banner
Startup Time
Startup-config Modified: 2005/08/22-19:54:01
Firmware Information
Firmware[1]
Updated Time
Firmware[2]
Updated Time
Current Firmware
Next Startup Firmware : [2]
Boot Loader
Timezone
(Next Boot)
Summer-Time
(Next Boot)
RS232C Baud-Rate
Management LAN Information
MAC Address
IP Address/Mask
Default Gateway
DNS Server
Domain Name
System Load Information
CPU Used Ratio
Memory Used Size
Check the version of firmware on which the XG700 is running and verify the system status based on CPU load and memory
usage.

6.1.3 Reviewing Log Messages

Log messages about the XG700 are classified into 4 levels -- CRITICAL, ERROR, WARNING, and INFO -- in accordance with
the severity of events.
To display event logs, run the
"show system
: (none)
: (none)
: XG700 E99L99 XF9999
: 2005/08/22-19:28:24
: E99L99 XF9999 2005/08/21-18:42:52
: 2005/08/21-22:08:12
: E99L99 XF9999 2005/08/22-19:27:12
: 2005/08/23-10:57:53
: [2]
: E10L10 XF0043
: gmt +0900
: gmt -800
: (none)
: M4.1.0/0200 M10.5.0/0200 0100
: 9600
: 0080.17c2.0500
: 192.168.41.22/24
: 192.168.41.1
: 192.168.77.20
: abc.efg.com
: 1%
: 36,429,824 bytes (57%)
"show
log" command in the operator EXEC mode or in the administrator EXEC mode.
220/266
All Rights Reserved, Copyright (C) PFU LIMITED 2005-2006
Displays status of fans.
good (normal-speed)
The port is working properly. The fan is working at a normal speed.
good (high-speed)
The port is working properly. The fan is working at a high speed.
Removed
Front fan 1 has been removed.
Check that front fan 1 is installed.
Front Fan-1 Speed is below the Low Limit. (xx)
It has been detected that the speed of front fan 1 is below limit.
Replace the fan unit.
Messages other than those above
Front fan 1 is not working properly. Replace the fan unit.
Status of rear fan 2
The messages and actions to take are the same as those described
for front fan 1.
Status of the fan installed in power supply unit
1The messages are the same as those described for front fan 1.
Replace the power supply unit.
Status of the fan installed in power supply unit 2
The messages are the same as those described for front fan 1.
Replace the power supply unit.
information" command in the operator EXEC mode or in the
"show system
information" command is entered.