A.2

List of Event Logs

This section provides message contents, explanation and actions to take that are associated with message ID and severity in
ascending numerical order. The solution is not provided for messages for which you do not take action.
A.2.1

env (Supervisory Control: 0-999)

Message ID
Severity
S0101
ERROR
P0105
INFO
P0106
INFO
P0107
INFO
S0108
ERROR
S0109
WARNING
P0110
INFO
%1$ Temperature is out of range. (%2$)
Explanation
A temperature error has been detected.
[[Inserted string]]%1$: Location at which a temperature error was detected.
Inlet: The temperature near the inlet
Internal: The temperature inside the chassis
[[Inserted string]]%2$: Temperature value
Solution
Perform the following concerning the set up of XG700:
Check that the air vent is not blocked.
Check that the temperature of the set up location is within the limits set out by the operation guarantee.
If the message is displayed even though the XG700 has been properly installed, note the message contents and
contact your XG700 sales representative.
PWR-%1$ is On Line.
Explanation
Power has returned to power supply unit.
[[Inserted string]]%1$: Power supply unit number
PWR-%1$ is Removed.
Explanation
It has been detected that power supply unit has been removed.
[[Inserted string]]%1$: Power supply unit number
Solution
If a message is received during times other than hot swapping, check the installation status.
PWR-%1$ is Inserted.
Explanation
It has been detected that power supply unit was installed.
[[Inserted string]]%1$: Power supply unit number
Solution
If a message is received during times other than hot swapping, check the installation status.
%1$ is out of range. (%2$)
Explanation
A voltage error has been detected.
[[Inserted string]]%1$: Displays the types of power supply faults (VDP/VDE/VDR/VDD/VDN/3.3V
Main/12V).
[[Inserted string]]%2$: Value that represents power supply fault
Solution
Note the message contents and contact your XG700 sales representative.
%1$ Speed is below the Low Limit. (%2$)
Explanation
It has been detected that the speed of fan is below limit.
[[Inserted string]]%1$: Displays a location at which a fan speed error was detected.
[[Inserted string]]%2$: Fan speed.
Solution
Replace the fan unit.
%1$ Speed is good.
Explanation
The speed of fan has returned to normal.
[[Inserted string]]%1$: Identifies the fan whose normal speed has been restored.
All Rights Reserved, Copyright (C) PFU LIMITED 2005-2006
Message/Explanation/Solution
Rear Fan-1: Rear fan 1
Rear Fan-2: Rear fan 2
PWR-1 Fan: Fan installed in power supply unit 1
PWR-2 Fan: Fan installed in power supply unit 2
Rear Fan-1: Rear fan 1
Rear Fan-2: Rear fan 2
PWR-1 Fan: Fan installed in power supply unit 1
PWR-2 Fan: Fan installed in power supply unit 2
233/266