Input/Output (I/O) Port: Connections And Wiring - AMX MAX-CSD ENCODER Instruction Manual

Max video encoder
Table of Contents

Advertisement

Input/Output (I/O) Port: Connections and Wiring

The I/O port responds to either switch closures, voltage level (high/low) changes, or it can be used
for logic-level outputs. You can connect up to two devices on this MAX unit.
FIG. 9 INPUT/OUTPUT connector
A contact closure between the GND and an I/O port is detected as a Push.
I/O Port Wiring Specifications
Pin
1
2
3
4
FIG. 10 shows the rear connectors on a MAX-CSE unit.
FIG. 10 MAX-CSE unit (rear view)
MAX Video Encoder
I/O
When used for voltage inputs, the I/O port detects a low (0 - 1.5 VDC) as a Push, and a
high (2.0 - 3.3 VDC) signal as a Release (this IO port uses 3.3V logic but can handle up
to 5V without harm).
When used for outputs, the I/O port acts as a switch to GND and is rated at 200 mA @
12 VDC. This device can utilize up to 2 I/O ports (see table below).
The PWR pin provides +12 VDC @ 200 mA and is designed as a power output for the
PCS2 or VSS2 (or equivalent).
The GND connector is a common ground and is shared by all I/O ports. A common
ground is shared with I/O ports 1 & 2 (see table below)
Signal
Function
GND
Signal GND
I/O 1
Input/Output
I/O 2
Input/Output
12 VDC
PWR