Monitoring Optical Power - Cisco 10720 - Internet Router Installation And Configuration Manual

Internet router
Hide thumbs Also See for 10720 - Internet Router:
Table of Contents

Advertisement

Chapter 3
Installing the Cisco 10720 Internet Router
1 SRP network interface(s)
509K bytes of non-volatile configuration memory.
16384K bytes of Flash internal SIMM (Sector size 512KB).
49152K bytes of Flash internal SIMM (Sector size 512KB).
Configuration register is 0x2102
Using the show environment all Command
Use the show environment all command to display temperature readings, voltage readings, and fan
status.
router# show environment all
Power Supplies:
Power Supply is ok.
Temperature readings:
chassis inlet measured at 27C/80F
chassis outlet0 measured at 33C/91F
chassis outlet1 measured at 32C/89F
Voltage readings:
Main Board :Voltage Ok
Access Card :Voltage Ok
Uplink Card :Voltage Ok
Fans:
Fan 1 status is believed to be ok.
Fan 2 status is believed to be ok.
Fan 3 status is believed to be ok.
Fan 4 status is believed to be ok.
Power Supply Fan status is believed to be ok.
Envm stats saved 1 time(s) since reload
Router#

Monitoring Optical Power

Optical power monitoring is used to monitor the SRP uplink interface. Use the show controllers srp
command.
Router# show controllers srp
Interface SRP1/1
Hardware is OC48 SRP
SRP1/1 - Side A (Outer RX, Inner TX)
OPTICS
RX readout values: -12 dBm - Within specifications
SECTION
LOF = 0 LOS = 0 BIP(B1) = 0
LINE
AIS = 0 RDI = 0 FEBE = 0 BIP(B2) = 0
PATH
AIS = 0 RDI = 0 FEBE = 0 BIP(B3) = 0
LOP = 0 NEWPTR = 0 PSE = 0 NSE = 0
Active Defects: None
Active Alarms: None
78-13062-10