Displaying Enabled Zone Configurations; Viewing The Enabled Zone Configuration Name Without Opening The Zone Administration Window; Viewing Detailed Information About The Enabled; Zone Configuration - Brocade Communications Systems 8 Administrator's Manual

Supporting fabric os v6.4.0
Hide thumbs Also See for 8:
Table of Contents

Advertisement

Displaying enabled zone configurations

The enabled zone configuration screen displays the actual content of the single zone configuration
that is currently enabled on the fabric, whether it matches the configuration that was enabled
when the current Zone Administration session was launched or last refreshed. The zones are
displayed, and their contents (ports, WWNs) are displayed next to them. Aliases are not displayed in
the enabled zone configuration. If there is no active zone configuration enabled on the switch, a
message displays to that effect.
NOTE
The enabled configuration is listed in the lower-right corner of the Zone Administration window.
Viewing the enabled zone configuration name without
opening the Zone Administration window
Use the following procedure to view the enabled zone configuration name:
1. Select a logical switch using the drop-down list under Fabric Tree section in the Switch Explorer
2. You can view the current zone configuration name (if one is enabled) in the lower portion of the

Viewing detailed information about the enabled

zone configuration

Use the following procedure to view detailed information about the enabled zone configuration.
1. Open the Zone Administration window, as described on
CAUTION
Clicking the refresh icon overwrites all local unsaved zoning changes. If anyone has made any
changes to the zones outside of your Zone Admin session, those changes are applied.
2. To identify the most recently effective zone configuration without saving or applying any
Web Tools Administrator's Guide
53-1001772-01
DRAFT: BROCADE CONFIDENTIAL
window.
The selected switch displays in the Switch View.
Switch Events and Switch Information window.
If no zone configuration is enabled, the field displays "No configuration in effect".
window"
on page 121.
The zone configuration in effect at the time you launched the Zone Administration window is
identified in the lower-right corner. It is also updated if you manually refresh the Zone
Administration window contents by clicking the refresh icon at the lower-right corner of the
Zone Administration window, or when you enable a configuration through the Zone
Administration window.
changes you made in the Zone Administration window, select Print > Print Effective Zone
Configuration in the Zone Administration window.
Zone configuration and zoning database management
"Opening the Zone Administration
9