Description
Message
Feeder self test failed
The self-test of the paper feeder failed. Perform a controlled power-down
Action
sequence on the scanner. If the problem persists, call Service.
Message
Front image cal unsuccessful
Action
The imaging calibration for the front camera was unsuccessful. Clean the imaging
guides and retry calibration. See Chapter 5, Maintenance, "Cleaning the imaging
guides" for cleaning procedures.
Message
Image address field overflow
One of the image address fields has exceeded its maximum configured count.
Action
Check to make sure that a level change was not missed or reconfigure the
scanner to allow a larger value for the overflowed field.
Message
Image buffer almost full
The feeder has stopped and the transport is still running because the image
Action
buffer is almost full. Processing will resume when the buffer is less full.
Message
Image buffer full
The image buffer overflowed.
Action
One or more documents that passed through the transport were not scanned.
Refeed all documents for which images were not obtained.
Message
Images in buffer
You tried to enable the scanner when images were still in the buffer. Not all
Action
images were retrieved. Retrieve the remaining images or clear the buffer. When
the buffer is cleared, you may enable the scanner.
Message
Interlocks are closed
Informational message. All doors are closed.
Action
Message
Interlocks are open
Action
One of the doors is not closed or an error has not been cleared since the door(s)
was last opened. Check to see that all doors are closed and clear the error by
pressing the Return arrow (left button) on the Control Panel.
Message
Invalid IA level
Action
The image address level you tried to enter is not valid. Re-enter a correct image
address level. For more information about image addressing, see Kodak
publication, Kodak i800 Series Scanners, Image Processing Guide, A-61510.
Message
IPB needs firmware
There is no firmware in an image processing board. Firmware needs to be
Action
installed in all image processing boards before scanning is possible. Call Service.
Message
Lamps not ready
Action
Calibration and/or scanning was attempted before the lamps were warmed up.
See Chapter 3, Operator Control Panel Function's for calibration guidelines and
procedures.
Message
Lamps ready for scanning
Action
Although lamps have warmed up sufficiently to allow scanning, image quality will
be best after the lamps have stabilized after approximately 10 minutes.