Common Area Type
7
Emergency,
Fire,
Flood,
Gas,
Temperature,
24-hour silent,
24-hour audible,
Non-alarm

Show Function

The show function is enabled during single/all
partition(s) status and displays information that is
relevant to the selected or all partitions.
Show All Partitions
In Ready mode press
show information on all partitions. Press
repeatedly to view memory / status content.
Show Single Partition
In Ready mode, press
partition number. The display will show information
relevant to the selected partition. Press
repeatedly to view memory / status content
Note: After 5 seconds of no button press there will
be a timeout and the display will revert to the all
partition display.

Siren

The siren is a common device to all partitions;
therefore, an alarm from one or more partitions will
activate a siren.
Siren Activity
The siren will be activated when receiving an
event from an alarmed device.
Overlapping activated sirens from different
partitions will not cause the siren active period
to be reset.
When there are several zones that are not
assigned to a common area and that are
alarmed in two or more partitions, the siren will
not stop until all partitions assigned to the
alarmed zones are disarmed.
D-302542
• Acts as a Delay type when at least one of the assigned partitions is
armed HOME.
• Will be ignored when at least one of the assigned partitions is
disarmed.
Always active.
, the display will
and then press the
Definition
Selecting a Partition
When operating in partition mode the first display will
read:
P1: R P2: N P3: R
Press
; the display will read:
SELECT PARTITION
Press
,
and
corresponding partition.
Note: After 5 seconds of no button press there will
be a timeout and the display will revert to the All
Partition display.
In case that the siren is active by an alarm from
a common area, and one of the partitions
assigned to this area disarms the system, the
siren will stop.
In case that the alarm is initiated from a
common area but continues with zones that are
not assigned to a common area, the siren will
not stop until all partitions assigned to the
alarmed zones are disarmed.
In case that there is a fire in partition 1 and a
burglary in partition 2, the siren will sound FIRE.
When partition 1 is disarmed the siren will
sound BURGLAR for the remainder of the siren
timeout period.