(First display)
READY
WALK TEST
USER SETTING
INSTALLER MODE
ENTER CODE
[installer code]
1. NEW INSTL CODE
2. ENROLLING
3. DEFINE ZONES
4. DEFINE PANEL
5. DEFINE COMM
9. DEFINE CUSTOM
10. DIAGNOSTICS
11. USER SETTINGS
12. FACTORY DEFLT
13. SERIAL NUMBER
14. START UL/DL
<OK> TO EXIT

4.15 ENABLING/DISABLING PARTITIONS

This menu allows you to enable/disable Partition Mode.
Partitioning allows you to divide the system into a
maximum of three independently controllable areas. Each
area can be armed / disarmed separately.
When the partition feature is disabled, zones, user codes
and features will operate the same as in a regular
PowerMaxExpress unit. When partition is enabled, menu
displays are changed to incorporate the partition feature.

4.16 DEFINING THE ARMING STATION

This mode allows you to customize the MKP-160 2way
keyprox device through the control panel and adapt the
device characteristics and behavior to the requirements of
the particular user.

4.16.1 Tamper Type

Enabling the function will enable a tamper open / close
message.
Available options are: disable and enable.
D-303973 PowerMaxExpress Installer's Guide
Displayed during
dialing process
Displayed during
download process
Download
Displayed for half
a minute approx.
accompanied by happy
(success) melody
Non-Partition
mode
READY 00:00
Figure 4.14 – Start UL/DL
If UL/DL server
tel. # is already
defined (see
par. 4.5.34)
COMMUNICATING
Dialing
OK
DOWNLOADING
OK
DOWNLOAD OK
DOWNLOAD FAILED
Partition
mode
P1 RDY 00:00
(First display)
WALK TEST
USER SETTING
INSTALLER MODE
ENTER CODE
[inst. code]
1. NEW INSTL CODE
15. PARTITIONING
<OK> TO EXIT
Note: Partitioning is an optional feature

4.16.2 Screen Saver

Enabling the function will turn off the display if no key is
pressed for more than several seconds.
Available options are: disable (ac) and enable.

4.16.3 Show AC Failure

Enable/disable AC failure indication on the keyprox device.
Available options are: disable and enable.
If UL/DL server
tel. # was not
defined before
(see par. 4.5.34)
TEL # NOT DEFINED
accompanied by sad
Dialing
failed
DIAL ATTEMPT FAIL
accompanied by sad
Download
failed
accompanied by sad
READY
enable
disable
Figure 4.15 – Partitioning
Displayed for half
a minute approx.
(failure) melody
Displayed for half
a minute approx.
(failure) melody
Displayed for half
a minute approx.
(failure) melody