Siren Behavior; Proximity Tags - Visonic POWERMAXPRO User Manual

Fully supervised wireless alarm control system
Hide thumbs Also See for POWERMAXPRO:
Table of Contents

Advertisement

SECURING THE PROTECTED SITE
B. Disarming after alarm, with all zones ready: If
the zone that alarmed in the armed state is back
to normal the disarming operation will progress
as shown:
PRESS
RESULTANT DISPLAY
CODE
READY
READY MEMORY
ARM indicator extinguishes.
To read the alarm memory, refer to Chapter 5.
The "MEMORY" message will disappear only
upon re-arming the system.
C. Disarming after an alarm, with one zone still
disturbed: If the zone that alarmed in the armed
state is still disturbed the disarming operation will
progress as shown:
PRESS
RESULTANT DISPLAY
CODE
NOT READY HH:MM
NOT READY MEMORY
ARM indicator extinguishes
To read the alarm memory, refer to Chapter 5.
The "MEMORY" message will disappear only
when you rearm the system.
If you do not know how to return the disturbed
zone to normal, consult your installer.
D. Disarming with the system in a state of
trouble: If trouble is detected in the armed
state, the TROUBLE indicator on the front panel
will light and the disarming operation will
progress as shown:
PRESS
RESULTANT DISPLAY
CODE
READY HH:MM
READY TROUBLE
ARM indicator extinguishes and
sounds once per minute,
To find out what kind of trouble is being sensed,
see Chapter 5. The TRBL display will disappear,
the TROUBLE indicator will extinguish and the
trouble beeps will stop upon eliminating the cause
for trouble.
12
_ _ _ _
HH:MM
(alternating)
_ _ _ _
(alternating)
_ _ _ _
(alternating)
E. Disarming after an alarm, with the system in a
state of trouble: The TROUBLE indicator on the
front panel will light. If the zone that alarmed while
the system was in the armed state reverts to
normal mode the disarming operation will progress
as shown:
PRESS
RESULTANT DISPLAY
CODE
READY HH:MM
READY TRBL
READY MEMORY
ARM indicator extinguishes and
sounds once per minute.
To find out which zone alarmed and what kind of
trouble is being sensed, see Chapter 5. The
TRBL display will disappear, the TROUBLE
indicator will extinguish and the trouble beeps will
stop upon eliminating the cause for trouble. The
MEMORY message will disappear only upon
rearming the system.
F. Disarming under Duress. If you are forcibly
compelled to disarm the system, enter the duress
code (2580 by default) or another code set by the
installer. Disarming will take place normally but a
silent alarm will be transmitted to the central
station.

Siren Behavior

The total siren time does not exceed the maximum
time as configured by the installer.
Continuously ON when initiated by a burglar zone
or a 24-hour zone, and when a user initiates a "panic
alarm".
When initiated by a fire zone (smoke is detected) ON -
ON - ON - pause - ON - ON - ON - pause - ........
and so on.
If there is nobody around to disarm the system upon
alarm, the siren will sound for the time duration set
by the installer - then will stop. The strobe light will
keep flashing until the system is disarmed.

Proximity Tags

Valid proximity tags enable you to perform variety of
functions without entering user code, for example,
arming, disarming, reading the event log, etc.
Whenever user code is required, you can simply
present a valid proximity tag instead of entering user
code.
_ _ _ _
(alternating)
(alternating)
D-302542

Advertisement

Table of Contents
loading