Errata
AI81.
Store to WT Memory Data May be Seen in Wrong Order by Two
Subsequent Loads
When data of Store to WT memory is used by two subsequent loads of one
Problem:
thread and another thread performs cacheable write to the same address the
first load may get the data from external memory or L2 written by another
core, while the second load will get the data straight from the WT Store.
Implication: Software that uses WB to WT memory aliasing may violate proper store
ordering.
Workaround: Do not use WB to WT aliasing.
For the steppings affected, see the Summary Tables of Changes.
Status:
AI82.
A MOV Instruction from CR8 Register with 16 Bit Operand Size
Will Leave Bits 63:16 of the Destination Register Unmodified
Moves to/from control registers are supposed to ignore REW.W and the 66H
Problem:
(operand size) prefix. In systems supporting Intel
when the processor is operating in VMX non-root operation and "use TPR
shadow" VM-execution control is set to 1, a MOV instruction from CR8 with a
16 bit operand size (REX.W =0 and 66H prefix) will only store 16 bits and
leave bits 63:16 at the destination register unmodified, instead of
storing zeros in them.
Implication: Intel has not observed this erratum with any commercially available software.
Workaround: None identified.
For the steppings affected, see the Summary Tables of Changes.
Status:
AI83.
Non-Temporal Data Store May be Observed in Wrong Program Order
When non-temporal data is accessed by multiple read operations in one
Problem:
thread while another thread performs a cacheable write operation to the
same address, the data stored may be observed in wrong program order (i.e.
later load operations may read older data).
Implication: Software that uses non-temporal data without proper serialization before
accessing the non-temporal data may observe data in wrong program order.
Workaround: Software that conforms to the Intel
Developer's Manual, Volume 3A, section "Buffering of Write Combining
Memory Locations" will operate correctly.
For the steppings affected, see the Summary Tables of Changes.
Status:
AI84.
Performance Monitor SSE Retired Instructions May Return Incorrect
Values
Performance Monitoring counter SIMD_INST_RETIRED (Event: C7H) is used
Problem:
to track retired SSE instructions. Due to this erratum, the processor may
®
Intel
Core™2 Extreme Processor X6800 and
®
Intel
Core™2 Duo Desktop Processor E6000 and E4000 Sequence
Specification Update
®
Virtualization Technology,
®
64 and IA-32 Architectures Software
51

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the E6600 - Core 2 Duo Dual-Core Processor and is the answer not in the manual?

Questions and answers

Table of Contents