Fn15: Print: Output Of Texts Or Q Parameter Values - HEIDENHAIN ITNC 530 User Manual

Conversational programming
Hide thumbs Also See for ITNC 530:
Table of Contents

Advertisement

FN15: PRINT: Output of texts or Q parameter
values
Setting the data interface: In the menu option PRINT or
PRINT-TEST, you must enter the path for storing the texts
or Q parameters. See "Assign," page 614.
FN15 cannot transfer data over the Ethernet interface.
The function FN15: PRINT transfers Q parameter values and error
messages through the data interface, for example to a printer. When
you save the data in the TNC memory or transfer them to a PC, the
TNC stores the data in the file %FN 15RUN.A (output in program run
mode) or in the file %FN15SIM.A (output in test run mode).
The data are transmitted from a buffer. Data output begins at the latest
by program end or when you stop the program. In the Single Block
mode of operation, data transfer begins at block end.
To output dialog texts and error messages with FN 15: PRINT
"numerical value"
Numerical values from 0 to
99:
Numerical values 100 and
above:
Example: Output of dialog text 20
67 FN15: PRINT 20
Outputting dialog texts and Q parameters with FN15: PRINT
"Q parameter"
Application example: Recording workpiece measurement.
You can transfer up to six Q parameters and numerical values
simultaneously. The TNC separates them with slashes.
Example: Output of dialog text 1 and numerical value for Q1
70 FN15: PRINT1/Q1
HEIDENHAIN iTNC 530
Dialog texts for OEM cycles
PLC error messages
547

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Itnc 530 e

Table of Contents