3-D Touch Probes
Pre-position at rapid traverse
Measure center misalignment of the stylus
when calibrating a triggering touch probe
M function for orienting the infrared sensor
before each measuring cycle
Angle of orientation for the infrared sensor
Difference between the current angle of
orientation and the angle of orientation set
in MP 6162; when the entered difference is
reached, an oriented spindle stop is to be
carried out.
Automatic operation: Automatically orient
the infrared sensor before probing to the
programmed probing direction
Manual operation: Compensate the probe
direction taking an active basic rotation into
account
Multiple measurement for programmable
probe function
Confidence range for multiple
measurement
Automatic calibration cycle: Center of the
calibration ring in the X axis referenced to
the machine datum
Automatic calibration cycle: Center of the
calibration ring in the Y axis referenced to
the machine datum
Automatic calibration cycle: Upper edge of
the calibration ring in the Z axis referenced
to the machine datum
Automatic calibration cycle: Distance below
the upper edge of the ring where the
calibration is carried out by the TNC
Radius measurement with the TT 130 touch
probe: Probing direction
644
MP6151
Pre-position with speed from MP6150: 0
Pre-position at rapid traverse: 1
MP6160
No 180° rotation of the 3-D touch probe during calibration: 0
M function for 180° rotation of the touch probe during calibration: 1 to 999
MP6161
Function inactive: 0
Orientation directly through the NC: -1
M function for orienting the touch probe: 1 to 999
MP6162
0 to 359.9999 [°]
MP6163
0 to 3.0000 [°]
MP6165
Function inactive: 0
Orient infrared sensor: 1
MP6166
Function inactive: 0
Take basic rotation into account: 1
MP6170
1 to 3
MP6171
0.001 to 0.999 [mm]
MP6180.0 (traverse range 1) to MP6180.2 (traverse range3)
0 to 99 999.9999 [mm]
MP6181.x (traverse range 1) to MP6181.2 (traverse range3)
0 to 99 999.9999 [mm]
MP6182.x (traverse range 1) to MP6182.2 (traverse range3)
0 to 99 999.9999 [mm]
MP6185.x (traverse range 1) to MP6185.2 (traverse range 3)
0.1 to 99 999.9999 [mm]
MP6505.0 (traverse range 1) to 6505.2 (traverse range 3)
Positive probing direction in the angle reference axis (0° axis): 0
Positive probing direction in the +90° axis: 1
Negative probing direction in the angle reference axis (0° axis): 2
Negative probing direction in the +90° axis: 3