HEIDENHAIN ITNC 530 User Manual page 168

Conversational programming
Hide thumbs Also See for ITNC 530:
Table of Contents

Advertisement

Abbr.
Input
RTOL
Permissible deviation from tool radius R for wear detection. If the
entered value is exceeded, the TNC locks the tool (statusL). Input
range: 0 to 0.9999 mm
DIRECT.
Cutting direction of the tool for measuring the tool during rotation
For tool length measurement: Tool offset between stylus center
TT:R-OFFS
and tool center. Preset value: Tool radius R (NO ENT means R).
TT:L-OFFS
Tool radius measurement: Tool offset in addition to MP6530
between upper surface of stylus and lower surface of tool.
Default: 0
LBREAK
Permissible deviation from tool length L for breakage detection. If
the entered value is exceeded, the TNC locks the tool (statusL).
Input range: 0 to 0.9999 mm
Permissible deviation from tool radius R for breakage detection. If
RBREAK
the entered value is exceeded, the TNC locks the tool (status L).
Input range: 0 to 0.9999 mm
Tool table: Tool data for automatic speed/feed rate calculation.
Abbr.
Input
Tool type: Press the SELECT TYPE (3rd soft-key row); the TNC
TYPE
superimposes a window where you can select the type of tool
you want. Functions are currently only assigned to the DRILL and
MILL tool types.
TMAT
Tool material: Press the SELECT MATERIAL soft key (3rd soft-key
row): The TNC superimposes a window where you can select the
type of material you want.
CDT
Cutting data table: Press the SELECT CDT soft key (3rd soft-key
row): The TNC superimposes a window where you can select a
cutting data table.
Tool table: Tool data for 3-D touch trigger probe (only when bit 1
is set in MP7411 = 1, also see the Touch Probe Cycles Manual)
Abbr.
Input
CAL-OF1
During calibration, the TNC stores in this column the center
misalignment in the reference axis of the 3-D probe, if a tool
number is indicated in the calibration menu.
CAL-OF2
During calibration, the TNC stores in this column the center
misalignment in the minor axis of the 3-D probe, if a tool number
is indicated in the calibration menu.
CAL-ANG
During calibration, the TNC stores in this column the spindle angle
at which the 3-D probe was calibrated, if a tool number is
indicated in the calibration menu.
168
Dialog
Wear tolerance: radius?
Cutting direction (M3 = –)?
Tool offset: radius?
Tool offset: length?
Breakage tolerance: length?
Breakage tolerance: radius?
Dialog
Tool type?
Tool material?
Name of cutting data table?
Dialog
Center misalignmt. in ref. axis?
Center misalignment minor axis?
Spindle angle for calibration?