Installation Manual
H3C SecPath F1000-S Firewall
II. Powering up the firewall
Turn on the switch of the site power.
Place the power switch(es) on the device into the ON position.
III. Checking/operating after power-up
After powering up the firewall, check that
The ventilation system is operating well.
After powering up the firewall, you can hear the sound of the fan blade spinning, and
feel the airflow when you put your hands close to the air vents.
The LEDs on the front panel of the chassis are in normal state.
See the section 1.2.3 "LEDs" for more information on LED state.
The console terminal display is correct.
After powering up the firewall, you can see the startup interface on the console terminal
(see section "4.1.3 Booting Process"). After the system passes Power-On Self-Test
(POST), press <Enter> as prompted. When "<H3C>" is displayed, you can proceed to
configure the firewall.
4.1.3 Booting Process
After being powered up, the firewall first runs the Boot ROM program. The terminal
screen displays the following system message:
Note:
The message displayed on the terminal may vary with Boot ROM versions.
**************************************************
*
*
*
**************************************************
Copyright(C) 2004-2007 by Hangzhou H3C Technologies Co.,Ltd.
Compiled at Wed Apr 12 17:39:36 CST 2006
Testing memory...OK!
512M bytes DDR SDRAM Memory
16M
Hardware Version is 2.0
CPLD
H3C SecPath Series Gateway Boot ROM V1.17 *
bytes Flash Memory
Version is 1.0
Chapter 4 Booting and Configuration
4-5
*
*