Operating Guide | VACON® 1000
Table 30: Technical Data for
(continued)
Control parameters
152
| Danfoss A/S © 2024.12
Motor control method
PID function
Modulation method
Acceleration/deceleration time
Protections
Functions
Analog input
Analog output
Digital input/output
Human-machine interface
Display parameters
Communication interface
U/F control
Sensorless Vector Control
Vector Control with speed feedback
Speed and torque control
Built-in PID regulator with configurable parameters
SPWM/SVPWM
0–3000 s (configurable)
Input overcurrent, input phase loss, input power loss, input under-
voltage, input overvoltage, input grounding, input sequence fault,
output overcurrent, output overload, output phase loss, output
grounding, output phase imbalance, output underload, electronic
motor thermal protection, motor stall, motor reverse, motor over-
speed, motor underspeed, speed setting analog loss, encoder ab-
normal, external fault, current sensor power fault, input current
sampling fault, output current sampling fault, motor winding over
temperature, motor bearing overtemperature, air filter clogged,
upstream main circuit breaker abnormal open, HV cabinet door
open, control power loss, transformer overtemperature, PLC-DSP
communication failure, cooling fan abnormal, UPS undervoltage,
fan power loss, transformer temperature sensor loss, PLC battery
voltage low, PLC-HMI communication failure, upstream main cir-
cuit breaker close/open failure, startup cabinet switch abnormal
open, startup cabinet switch close/open failure, cooling fan failure
Speed ramps selection, S-curve, frequency skip, multi-point V/F,
torque boost, AVR, dead-band compensation, Jog, flying start, DC
braking, field weakening, energy saving operation, droop control,
speed feedforward control, overvoltage prevention during decel-
eration, power cell symmetrical bypass, negative sequence com-
pensation, input undervoltage derating, low voltage ride through,
automatic restart, synchronous transfer, multi motor parameter
storage, system auto bypass
0–10 V/4–20 mA, 2 channels
0–10 V/4–20 mA, 4 channels
7 sets input (standard, expandable)
10 sets output (standard, expandable)
7" touch screen (standard)
10" touch screen available as option
Target speed
Output speed
Input/output currents
Operation status indication
Standard: Modbus RTU
Options: PROFIBUS DP (DP-V0), DeviceNet ™ , Modbus TCP,
PROFINET I/O, EtherNet/IP ™ , EtherCAT®, CANopen®, POWERLINK,
ControlNet ™
Specifications
AQ363633621020en-000401 / 172F3117D