Table 4-24. omconfig system platformevents (continued)
Event Name
event=fanfail
event=hardwarelogfail
event=intrusion
event=powerwarn
event=powerabsent
event=powerfail
event=processorwarn
event=processorfail
event=processorabsent
event=redundegrad
event=redunlost
event=tempwarn
event=tempfail
event=voltfail
event=watchdogasr
94
omconfig: Managing Components Using the Instrumentation Service
Description
Sets action or enables/disables alert generation when a fan probe detects that the
fan is running too slow or not at all.
Enables/disables alert generation when a hardware log detects a failure value.
Sets action or enables/disables alert generation when a chassis has been opened.
Sets action or enables/disables alert generation when a power device probe detects
that the power supply, voltage regulator module, or DC to DC converter is
pending a failure condition.
Sets action or enables/disables alert generation when a processor probe detects
that the power supply is absent.
Sets action or enables/disables alert generation when a power device probe detects
that the power supply, voltage regulator module, or DC to DC converter has failed.
Sets action or enables/disables alert generation when a processor probe detects
that the processor is running at less than peak performance or speed.
Sets action or enables/disables alert generation when a processor probe detects
that the processor has failed.
Sets action or enables/disables alert generation when a processor probe detects
that the processor is absent.
Sets action or enables/disables alert generation when the system's fans and/or
power supplies become inoperative, resulting in less than full redundancy for that
component.
Sets action or enables/disables alert generation when the system's fans and/or
power supplies become inoperative, resulting in a lost or a "no redundant
components working" condition for that component.
Sets action or enables/disables alert generation when a temperature probe detects
that the temperature is approaching the maximum high or low limits.
Sets action or enables/disables alert generation when a temperature probe detects
that the temperature is either too high or low for proper operation.
Sets action or enables/disables alert generation when a voltage probe detects that
the voltage is too low for proper operation.
Enables or disables alert generation configured by the ASR when the system has
hung or is not responding.