Table 4-1. omconfig Command Level 1, Level 2, and Level 3 (continued)
Command
Command
level 1
level 2
chassis
Command
User privilege
level 3
required
platformevents A
recovery
P , A
shutdown
A
thrmshutdown A
webserver
A
biossetup
A
bmc
A
currents
P , A
fans
P , A
fancontrol
P , A
frontpanel
A
info
P , A
leds
P , A
omconfig: Managing Components Using the Instrumentation Service
Use
Determines the shutdown action, if any, to be
taken for a specific platform event. Also,
enables and disables platform events filter
alert generation.
Determines in advance how your system
responds to a hung operating system.
Allows the administrator to select from several
options when shutting down the system.
Sets the severity level at which a thermal event
triggers a system shutdown.
Starts or stops the Web server.
Configures behavior of specific system
components that are controlled by the BIOS.
Configures remote access information.
NOTE:
This subcommand will be phased-out in
future releases and replaced by the
subcommand remoteaccess.
Configures current probe warning thresholds
by default or by value.
Configures fan probe warning thresholds by
default or by value.
NOTE:
You cannot change threshold values on
embedded server management (ESM3) and
Dell™ PowerEdge™ x8xx systems.
Allows you to optimize fan speed for
maximum cooling or quiet operation.
Configures the Power button and Nonmasking
Interrupt (NMI) button if present on
the system.
Allows you to set an initial value for, or to edit
the value for, asset tag or chassis name.
Specifies when to flash a chassis fault LED or
chassis identification LED, and allows you to
clear the LED for the system's hard drive.
53