Omconfig Reset All Temperature Probe Thresholds; Omconfig Blink - Dell Command Line Interface User Manual

Dell command line interface user's guide
Table of Contents

Advertisement

Example Syntax
For example, you may want to specify the minimum and maximum warning thresholds for all
temperature probes to 10 and 40
Example for SAS Controllers
In this example, the temperature probes reside in enclosure 3 attached to connector 2 on controller 1.
To set the thresholds for all temperature probes to 10 and 40
omconfig storage enclosure action=setalltempprobes controller=1
enclosure=2:3 minwarn=10 maxwarn=40

omconfig Reset All Temperature Probe Thresholds

Use the following omconfig command syntax to reset the minimum and maximum warning temperature
thresholds back to their default value for all temperature probes in the enclosure.
NOTE:
This command is not supported on SCSI RAID controllers.
Complete Syntax
omconfig storage enclosure action=resetalltempprobes controller=id
enclosure=<ENCLOSUREID>
where id is the controller ID. The <ENCLOSUREID> variable specifies the enclosure.
Example Syntax
For example, you may want to reset the thresholds for all temperature probes in enclosure 2 on
controller 1.
Example for SAS Controllers
In this example, the temperature probes reside in enclosure 3 attached to connector 2 on controller 1.
To reset the thresholds for all temperature probes, enter:
omconfig storage enclosure action=resetalltempprobes controller=1
enclosure=2:3

omconfig Blink

Use the following omconfig command to blink the light-emitting diodes (LEDs) on the enclosure.
Complete Syntax
omconfig storage enclosure action=blink controller=id enclosure=
<ENCLOSUREID>
where id is the controller ID. The <ENCLOSUREID> variable specifies the enclosure.