omreport chassis Commands

Use omreport chassis commands to view details for the entire chassis or for a particular component.

omreport chassis

When you type:
omreport chassis
Server Administrator displays a general status for your main system chassis components.
NOTE:
When you issue CLI commands to a server module in a modular system, chassis refers only to the server module.
NOTE:
As with all output shown in this guide, the following output is an example and may vary depending on your
system configuration.
SEVERITY
: COMPONENT
Ok
: Fans
Critical
: Intrusion
Ok
: Memory
Ok
: Power Supplies
Ok
: Temperatures
Ok
: Voltages

omreport chassis acswitch

Use the omreport chassis acswitch command if your system has redundant AC power lines that are
configured in a failover arrangement. When you type:
omreport chassis acswitch
Server Administrator displays the following output:
AC Failover Switch
AC Switch Redundancy
Redundancy Status
Number of devices required for full
redundancy
Redundancy Mode
Redundancy Configuration
26
omreport: Viewing System Status Using the Instrumentation Service
: Full
: 2
:
: Input Source Line 1, upon
redundancy restoration, return
to Line 1