I
NSTALLATION
100 Mbps Fast Ethernet Collision Domain
SMC 3 - 2 Rule for Class
Between any two PCs or other stations in the same 100BASE-T
collision domain, there may be:
• up to 3 link segments and
• up to 2 Class II repeaters (hubs)
SMC 2 - 1 Rule for Class I and Class II Repeaters
Between any two PCs or other stations in the same 100BASE-T
collision domain, there may be:
• up to 2 link segments and
• only 1 Class I or Class II repeater (hub)
Maximum 100BASE-T Network Diameter
Repeater Type
and Number
1 Class I
1 Class II
2 Class II
Maximum 100BASE-T Cable Distance
Cable Type
T
wisted Pair
Fiber
MII
3-10
Twisted Pair
100BASE-TX/T4 100BASE-T4/FX
200 m (656 ft.)
200 m (656 ft.)
205 m (672.4 ft.)
Connecting
Any two devices
Switch to Switch, Server or PC
Half duplex
Full duplex
Any two devices
II
Repeaters
Twisted Pair/Fiber
231 m (757.7 ft.)
304 m (997.1 ft.)
236.3 m (775.1 ft.) 216.2 m (709.1 ft
100BASE-TX/FX
260.8 m (855.4ft.)
308.8 m (1012.9 ft.)
Max. Distance
100 m (328 ft.)
412 m (1,351.4 ft.)
2 km (1.24 mi.)
0.5 m (1.6 ft.)
.)