Download Print this page

RoboLabs Vortex Popcorn Robopop 60 Instruction Manual page 11

Hide thumbs Also See for Vortex Popcorn Robopop 60:

Advertisement

3.3
Electric requirements
The machine requires 3 phase 400 V 50 Hz five-wire system
3P+N+PE 32 A 400 V pin and sleeve connector (IEC 60309). Connecting to the mains must be
arranged in conformity with all requirements applicable in the country of use at the moment
of commissioning. The machine has a 3P 32 A circuit breaker with rated short-circuit capacity
6 kA at its input.
Equipotential bonding wire (up to 10 sq.mm) shall be connected to screw terminal on the base
frame marked with IEC 60417-5021 sign: IEC 60417-5021:
Check the voltage in the receptacle. Check the grounding in the receptacle. Plug the
machine in. Make sure that the supply cord is not twisted, pulled, and is not mechanically
impacted in any other way; and also is not in contact with hot surfaces.
3.4
First start (operation check)
ATTENTION! Machine that was kept for a long time at temperatures below 0 °C must be kept
in normal room temperature (20-22 °C) not less than 12 hours before first start.
Follow these steps to check the machine operation:
1. Release the Emergency stop switch (if actuated).
2. Press START push button.
3. Wait until HMI screen load complete.
4. Press and hold TURN OFF button on the screen for 1 second.
5. Unplug the machine.
2
One phase is not used.
2
(L1-L2-L3-N-GND). Use
10