CYBEX Arc Trainer 770A Service Manual page 75

Cardiovascular systems
Hide thumbs Also See for Arc Trainer 770A:
Table of Contents

Advertisement

ERROR 27 - LOW BATTERY
Note ERROR 27 present
in log. Restart unit.
Does the error
reoccur after restart?
Yes
Check battery voltage in
diagnostic mode. Voltage
needs to be above 12.5
VDC in order for incline to
function properly
does the battery
check out properly?
Yes
Check battery to LCB
cable and verify voltage is
present at LCB
Is there voltage
present at LCB?
Yes
Lower controller battery
charge circuit is defective.
replace LCB
Yes
Cybex Service Manual
Charge or replace battery
No
Replace battery to LCB
No
cable.
75
Completed
No

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Arc Trainer 770A and is the answer not in the manual?

Subscribe to Our Youtube Channel

Table of Contents