Pavone Systems DAT 700 Technical Manual page 13

Serial and analog weighing indicator/transmitters
Table of Contents

Advertisement

I
Access to this menu is allowed only in case of FREE operation or in
case of password access by authorized personnel (in case of METRIC- operation)
Sub
Message
Menu
RES0LV.
L.C. CAP.
L.C. SEN.
SYST.FS
CAL1BR.
DEAD L.
CAL.TYP
DEAD W.
TABLE
G-CAL
G-USE
(*) The setting of division values by fieldbus is done differently from that done by instrument. Refer to addresses 1101 and 1102 in
the Modbus register table.
(**) These parameters are displayed only in the case of METRIC operation.
DAT700 Instrument User Manual
CALIBRATION SETTINGS
Name
Value of a single division, expressed
in kg. The ratio of the system's
maximum capacity to the division
value constitutes the system's
Division
resolution (number of divisions). As a
Value
result of changing the division value,
if the maximum capacity is not
changed, the weight calibration is
automatically corrected.
Enter the value of the sum of the
nominal capacities of the load cells,
Load cells
expressed in the selected unit of
capacity
Following the change of this value,
theoretical calibration is performed.
Set the value corresponding to the
average of the load cell sensitivities,
Load cells
in mV/V. Following the
Sensitivity
modification of the sensitivity value,
the theoretical weight calibration is
Maximum capacity limit of the
system. Following the change, the
Scale Bottom
analog output scale bottom value is
Programming the fixed tare value (in
kg). Following the change, a zero-tare
Fixed tare
calibration is performed.
Selection of the type of calibration.
Calibration
Upon confirmation, one of the
following procedures is initiated.
Dead Weight
Zero and Sample Weight calibration
calibration
and linearization to sample weights
(***)
Table calibration (****)
Calibration
Acceleration of gravity at the weight
Gravity
calibration site. (**)
Acceleration of gravity at the site of
Use Gravity
instrument use. (**)
Description
measurement.
performed.
set.
Type
De-
Range
fault
0,0001 ÷ 50
1
Sel.
Steps 1,2,5
0
Com.
0 ÷ 999999
2 mV/
Com.
0.1 ÷ 4 mV/V
V
0 ÷ Cell
0
Com.
capacity
0
Com.
0 ÷ Capacity
Dead Weight or
Sel.
Table
Spc
Spc
977000
0
Com.
÷
984000
977000
Com.
0
÷
984000
Ind.Fi
eldbus
(*)
1103
(MSB)
1104
(LSB)
1105
1301
(MSB)
1302
(LSB)
1106
(MSB)
1107
(LSB)
501÷
503
1151÷
1172
1108
(MSB)
1109
(LSB)
1110
(MSB)
1111
(LSB
pag. 13