Auxiliary Area - Omron CJ - 09-2009 Operation Manual

Programmable controllers
Table of Contents

Advertisement

A000 to A447: Read-only Area, A448 to A959: Read/Write Area
Read-only Area (Set by System)
Address
Name
Words
Bits
A000
---
10-ms Incre-
menting Free
Running
Timer
A001
---
100-ms Incre-
menting Free
Running
Timer
A002
---
1-s Increment-
ing Free Run-
ning Timer
A050
A05000
Basic I/O Unit
to
Information,
A05007
Rack 0 Slot 0
A05008
Basic I/O Unit
to
Information,
A05015
Rack 0 Slot 1
A051 to
A05100
Basic I/O Unit
A069
to
Information,
A06915
Racks 2 to 7
A090 to
---
User Program
A093
Date
A094 to
---
Parameter
A097
Date
Appendix C

Auxiliary Area

Function
This word contains the system timer used after the
power is turned ON.
0000 hex is set when the power is turned ON and
this value is automatically incremented by 1 every
10 ms. The value returns to 0000 hex after reaching
FFFF hex (655,350 ms), and then continues to be
automatically incremented by 1 every 10 ms.
Note: The timer will continue to be incremented
when the operating mode is switched to RUN
mode.
Example: The interval can be counted between pro-
cessing A and processing B without requir-
ing timer instructions. This is achieved by
calculating the difference between the
value in A000 for processing A and the
value in A000 for processing B. The inter-
val is counted in 10 ms units.
This word contains the system timer used after the
power is turned ON.
0000 hex is set when the power is turned ON and
this value is automatically incremented by 1 every
100 ms. The value returns to 0000 hex after reaching
FFFF hex (6,553,500 ms), and then continues to be
automatically incremented by 1 every 100 ms.
Note: The timer will continue to be incremented
when the operating mode is switched to RUN
mode.
This word contains a system timer used after the
power is turned ON
0000 hex is set when the power is turned ON and
this value is automatically incremented by 1 every
1 s. The value returns to 0000 hex after reaching
FFFF hex (65,535 s), and then continues to be auto-
matically incremented by 1 every 1 s.
Note: The timer will continue to be incremented
when the operating mode is switched to RUN
mode.
A bit will turn ON to indicate when the load short-cir-
cuit protection function alarm output has been given.
Only the 4 most LSB are used for the CJ1W-OD202
(2 points per bit), only the LSB is used for the CJ1W-
OD212, OD204, MD232 and only the two most LSB
are used for the CJ1W-OD232. Each bit indicates the
status for one circuit.
1: Short circuited
0: Normal
These words contain in BCD the date and time that
the user program was last overwritten.
A09000 to A09007: Seconds (00 to 59)
A09008 to A09015: Minutes (00 to 59)
A09100 to A09107: Hour (00 to 23)
A09108 to A09115: Day of month (01 to 31)
A09200 to A09207: Month (01 to 12)
A09208 to A09215: Year (00 to 99)
A09308 to A09307: Day of the week
(00: Sunday, 01: Monday, 02: Tuesday, 03: Wednes-
day, 04: Thursday, 05: Friday, 06: Saturday)
These words contain in BCD the date and time that
the parameters were last overwritten.
The format is the same as above
Status
Status
Write timing/
after
at star-
Related flags,
mode
tup
settings
change
Retained Cleared
Every 10 ms after
power is turned ON
CPU Unit with unit ver-
sion. 3.0 or later
Retained Cleared
Every 100 ms after
power is turned ON
CPU Unit with unit ver-
sion. 3.0 or later
Retained Cleared
Every 1 s after power is
turned ON
CPU Unit with unit ver-
sion. 4.0 or later
---
---
Refreshed each cycle.
---
---
---
---
Retained Retained Not supported by
CJ1@-CPU@@ CPU
Units
Retained Retained Not supported by
CJ1@-CPU@@ CPU
Units
597

Advertisement

Table of Contents
loading