Omron CJ - 09-2009 Operation Manual page 112

Programmable controllers
Table of Contents

Advertisement

Function Tables
Purpose
Maintenance
Changing the program
and Debug-
while it is being executed.
ging
Sampling I/O Memory data.
• Periodic sampling
• Sampling once each
cycle
• Sampling at specified
times
Confirming there are no
errors in instruction execu-
tion.
Recording the time that
power was turned on, the
last time that power was
interrupted, the number of
power interruptions, and
the total PLC ON time.
Replacing the program
without stopping operation.
Reading the time/date
when the user program
was changed.
Reading the time/date
when the parameter area
was changed.
Programming/monitoring
the PLC remotely.
• Programming or monitor-
ing a PLC on the network
through Host Link.
• Programming or monitor-
ing
a
modems.
Programming/monitoring
PLCs in other networks
Error Pro-
Generating a non-fatal or
cessing and
fatal error for user-defined
Troubleshoot-
conditions.
ing
• Non-fatal
operation continues.)
• Fatal errors (PLC opera-
tion stops.)
• Not
recording
defined alarms and errors
in the error log.
Analyzing time and logic in
execution of an instruction
block.
Recording the time/date of
errors and error details.
Reading recorded error
details.
64
Use the online editing function from a
Programming Device.
(Several instruction blocks can be
changed with CX-Programmer.)
Data trace at regular intervals
Data trace at the end of each cycle
Data trace each time that TRSM(045)
is executed
Set the PLC Setup to specify the
desired operating mode at start-up.
(Startup Mode)
Read the Auxiliary Area words con-
taining power supply information.
Startup Time: A510 and A511
Power Interruption Time: A512 and
A513
Number of Power Interruptions: A514
Set the PLC Setup so that instruction
errors are treated as fatal errors.
(Instruction Error Operation)
Host Link → Network Gateway func-
tion
Host Link through modems
PLC
through
Communicate with PLCs up to two
network levels away through Control-
ler Link or Ethernet.
FAILURE ALARM: FAL(006)
errors
(PLC
SEVERE FAILURE ALARM:
FALS(007)
Set the PLC Setup so that user-
defined FAL errors are not recorded in
user-
the error log.
FAILURE POINT DETECTION:
FPD(269)
Use the error log function. Up to 20
error records can be stored.
Function
Section 1-8
Manual
Reference
Programming
7-2-3 Online
Manual
Editing
(W394)
7-2-4 Data
Tracing
6-4 Startup
Settings and
Mainte-
nance
6-4-5 Clock
Functions
2-3-3
Checking
Programs
2-5
Operation
Expanded
Manual
System
Configura-
tion
Programming
6-5 Diag-
Manual
nostic and
(W394)
Debugging
Functions