Omron CJ - 09-2009 Operation Manual page 679

Programmable controllers
Table of Contents

Advertisement

Auxiliary Area
Addresses
Name
Word
Bit
A744 to
Power ON
A746
Clock Data 9
(See note.)
A747 to
Power ON
A749
Clock Data
10 (See
note.)
Note This data is supported by CPU Units with unit version 3.0 or later.
Note In CJ-series PLCs, the following flags are provided in a special read-only area and can be specified with
the labels given in the table. These flags are not contained in the Auxiliary Area.
Flag area
Condition Code
Error Flag
Area
Access Error Flag
Carry Flag
Greater Than Flag
Equals Flag
Less Than Flag
Negative Flag
Overflow Flag
Underflow Flag
Greater Than or Equals
Flag
Not Equal Flag
Less than or Equals Flag <=
Always ON Flag
Always OFF Flag
Clock Pulse
0.02-s clock pulse
Area
0.1-s clock pulse
0.2-s clock pulse
1-s clock pulse
1-min clock pulse
Function
These words contain the time at
which the power was turned ON
eight times before the startup time
stored in words A510 to A511.
A74400 to A74407: Seconds (00 to
59)
A74408 to A74415: Minutes (00 to
59)
A74500 to A74507: Hour (00 to 23)
A74508 to A74515: Day of month (00
to 31)
A74600 to A74607: Month (01 to 12)
A74608 to A74615: Year (00 to 99)
These words contain the time at
which the power was turned ON nine
times before the startup time stored
in words A510 to A511.
A74700 to A74707: Seconds (00 to
59)
A74708 to A74715: Minutes (00 to
59)
A74800 to A74807: Hour (00 to 23)
A74808 to A74815: Day of month (00
to 31)
A74900 to A74907: Month (01 to 12)
A74908 to A74915: Year (00 to 99)
Name
Label
ER
Turns ON when an error occurs in processing an instructions, indi-
cating an error end to the instruction.
AER
Turns ON when an attempt is made to access an illegal area. The
status of this flag is maintain only during the current cycle and only
in the task in which it occurred.
CY
Turns ON when there is a carry or borrow in a math operation,
when a bit is shifted into the Carry Flag, etc.
>
Turns ON when the result of comparing two values is "greater
than," when a value exceeds a specified range, etc.
=
Turns ON when the result of comparing two values is "equals,"
when the result of a math operation is 0, etc.
<
Turns ON when the result of comparing two values is "less than,"
when a value is below a specified range, etc.
N
Turns ON when the MSB in the result of a math operation is 1.
OF
Turns ON when the result of a math operation overflows.
UF
Turns ON when the result of a math operation underflows.
>=
Turns ON when the result of comparing two values is "greater than
or equals."
<>
Turns ON when the result of comparing two values is "not equal."
Turns ON when the result of comparing two values is "less than or
equals."
A1
This flag is always ON.
A0
This flag is always OFF.
0.02s
Repeatedly turns ON for 0.02 s and OFF for 0.02 s.
0.1s
Repeatedly turns ON for 0.1 s and OFF for 0.1 s.
0.2s
Repeatedly turns ON for 0.2 s and OFF for 0.2 s.
1s
Repeatedly turns ON for 1 s and OFF for 1 s.
1min
Repeatedly turns ON for 1 min and OFF for 1 min.
Settings
Status
Status at
after
startup
mode
change
See at left.
Retained Retained Written when power is
See at left.
Retained Retained Written when power is
Meaning
Appendix C
Write timing/
Related Flags,
Settings
turned ON.
turned ON.
631

Advertisement

Table of Contents
loading

Table of Contents