Compressor; Compressor Cooling Fan; Drum Motor - Electrolux EDR 2000 Service Manual

Heat pump dryer
Hide thumbs Also See for EDR 2000:
Table of Contents

Advertisement

5.2 Compressor

The compressor drives the cooling agent (R134a) circulation of the
heat pump.
Power consumption
Widerstand main coil
Widerstand auxiliary coil
Überlastungs-
Kompressor
schutz
Motorkondensator

5.3 Compressor cooling fan

Axial fan fitted with ball bearings,
power consumption 23 watts,
2600 – 3000 rpm

5.4 Drum motor

Drum motor – The motor assembly consists of a belt tensioner
and the single-phase asynchronous motor (3), with
anti-overheating circuit breaker.
The efficiency of the motor can be checked by measuring the
resistance across the windings:
Winding A Ohm 29 ~ (contacts 1-3)
Winding B Ohm 29 ~ (contacts 2-3)
The motor is powered by the electronic board via a relay (which
determines the direction of rotation) and a triac.
The motor condenser (9uF) is mounted on the cover of the condensate
pump and the floater chamber.
06.2005 R.Kurzke
550 Watt.
3,6 Ohm
7,0 Ohm
Total weight 14 kg
Oil filling
Öil
Netz
320 ccm
ISO VG 22 ESTER
Compressor motor condenser
16 uF/400V
- 11 -
599 522 797 EN

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents